| 
					
					
					
					  WATER SALINITY and Total 
					dissolved 
					
					solids The salinity 
					of a water sample can be described numerically in several 
					different ways, each with a confusing set of measurement 
					units. This page covers the summation of water chemistry
					analysis data and conversions between total dissolved solids 
					(TDS), equivalent NaCl content, and chloride content.
					Conversion of salinity to water resistivity is covered on 
					the next Section in this Chapter.
 
 
 
 
  Equivalent NaCl 
					 
					Water Salinity
			from Water Analysis The
				resistivity of a water sample can be calculated from its
				chemical analysis. To do this, an equivalent NaCl concentration
				must be determined based on the ionic activity of each ion.
 
					  
					  
					  
					
					
 
			
			 Enter chart with total solids concentration of the sample in ppm
			(mg/kg) to find weighting factors for each ion present. The
			concentration of each ion is multiplied by its weighting factor, and
			the products for all ions are summed to obtain equivalent NaCl
			concentration.
 
 
			The math is
			pretty simple:1: TDS = SUM (IONi)
 2:
                WSe = SUM (IONi * FACTRi)
 
			Where:TDS = total dissolved solids (ppm)
 IONi = ion concentration of ith component (ppm)
 FACTRi = multiplier factor for ith component (ppm)
 WSe = equivalent NaCl concentration (ppm)
 
 
  NUMERICAL EXAMPLE: Assume formation-water sample analysis
 460 ppm Ca,
 1400 ppm SO4
 19,000 ppm Na plus Cl.
 
 Total dissolved solids concentration
 TDS = 460 + 1400 + 19,000 = 20,860 ppm
 Entering the chart with this total solids concentration
 Ca multiplier = 0.81
 SO4 multiplier = 0.45
 Na+CL multiplier = 1.00
 Equivalent NaCl concentration = 460 ´ 0.81 + 1400 ´ 0.45 + 19,000 ´
			1.0 = 20,000 ppm.
 
					
			
			 Water Salinity from
			Chloride Content Sometimes salinity is reported at the well site in ppm Chlorides
			instead of ppm NaCl equivalent.
 6: WSa = Ccl * 1.645
 Where:Ccl = water salinity (ppm Cl)
 WSa = water salinity (ppm NaCl)
 
					
			 COMMENTS: Use this relationship when chloride content of the water sample
				is known. Usually Cl content is derived at the
				well site from a drill stem test recovery. It is useful as a
				first approximation until the water sample is analyzed more
				accurately at a laboratory. The relationship is for pure NaCl
				solutions and the factor may be higher or lower if other ions
				are present.
 
					
					 NUMERICAL
                EXAMPLE: 1. Chloride concentration to salinity.
 WS = 11,600 ppm Cl * 1.645 = 19,000 ppm NaCl
 
 |